2 items
 
  • EX190-S
  • EX190-S
s_2059
  • EX190-S
  • Compare

 

EX190

1MP 48cm (19") COLOR LCD MONITOR
Calibration compliant with the DICOM Part 14 standard.
Model RRP (Excl. VAT)
 

 

Perfect Image Reproduction thanks to IPS LCD Technology

The LCD technology used eliminates picture geometry distortions and color spots. The monitor delivers flicker-free images, even at low refresh rates (60 Hz). In addition, IPS technology guarantees improved contrast values and significantly higher viewing angle stability. The result is a device that meets the highest ergonomic requirements.


Individualized Color Point Adjustment

The monitor's default blue color location can be adjusted to individual requirements using a color slider. This enables color adjustment in the field such as when replacing a monitor. The adjustment can be performed via the On Screen Display (OSD) without external tools such as a luminance meter or calibration software.

Monitor - EX190 - Individualized Color Point Adjustment

Support of Complex Timing Requirements

Although the monitor automatically detects standard video signals, older medical devices frequently cause problems due to their unusual
timing. These special application requirements can be met using the Force Mode function.

Freely Adjustable User Lookup Table (LUT)

The adjustable LUT makes it possible for LUT recalculations to be initiated manually. Within this recalculation the gamma model, luminance settings, or color parameters can be modified. The LUT is calculated via OSD menu without having to access external calibration software. The reset LUT is calculated immediately, saved in the device, and used immediately for image display. This provides the user with the ability to establish the user LUT individually without using luminance meter.

Display of Different Signal Resolutions

The optimum screen resolution is 1280 x 1024 pixels. Video signals with other resolutions, common in medical technology, are automatically adapted to the screen size. Alternatively they can be displayed in original size (1:1).

Consistency thanks to DICOM Part 14 Factory Calibration

The monitor is precalibrated to meet the DICOM Part 14 standard, thereby ensuring permanently consistent image transmission. The five default look-up tables (LUTs) contain practice-based settings. They take into account the DIN 6868-157 room classes, thereby meeting current pecifications for diagnostic monitors.


Constant Luminance Regulation

An integrated brightness sensor, using EIZO fully automated brightness control, ensures fast luminance stabilization during system start and compensates for fluctuations that occur in the course of operation due to differing ambient temperatures.

Monitor - EX190 - Luminance Regulation

Cascading multiple monitors

The integrated Loop-Through output (BNC video / SoG signal) enables connection with multiple other monitors or image archiving in the operating room.

Installation on a VESA Ceiling Suspension

Compliance with the VESA standard enables attachment to existing mounting accessories.

Versatile Positioning for Improved Ergonomics

EIZO's highly versatile stand offers tilt, swivel and a wide height adjustment range enabling you to use the monitor with greater comfort.


Environmentally-Friendly LED Backlight

By utilizing an energy-efficient LED as a backlight, the monitor achieves a high-brightness and low power consumption at the same time. In contrast to conventional CCFL technology, LED backlighting offers a longer monitor lifespan, is free of hazardous materials, and is therefore compliant with current environmental regulations.

Monitor - EX190 - LED Backlight

Customer Assurance with Medical Standards

The monitor meets the strictest medical, safety, and EMC emission standards.

Model variations
Cabinet color
Panel
Type
Backlight
Size
Native resolution
Viewable image size (H x V)
Pixel pitch
Pixel density
Grayscale tones
Display colors
Viewing angles (H / V, typical)
Brightness (typical)
Recommended brightness for calibration
Contrast ratio (typical)
Response time (typical)
Wide gamut coverage (typical)
Video signals
Input terminals
Output terminals (loop through)
Digital scanning frequency (H / V)
Analog scanning frequency (H / V)
Sync formats
Network
Wired LAN
USB
Function
Standard
Audio
Speakers
Input terminals
Output terminals
Sound adjustment
Power
Power requirements
Maximum power consumption
Typical power consumption
Power save mode
Standby mode
Power management
Self-calibration
Sensor
Features & functions
Preset modes
Auto EcoView / BrightRegulator
EcoView Sense
Brightness Stabilization
Digital Uniformity Equalizer
OSD Languages
Others
Communication Protocol
Physical specifications
Dimensions (Landscape, W x H x D)
Dimensions (Without stand, W x H x D)
Dimensions (Panel mount, W x H x D)
Net weight
Net weight (Without stand)
Net weight (With hood)
Net weight (Panel mount)
Height adjustment range
Tilt
Swivel
Pivot
Hole spacing (VESA standard)
Environmental requirements
Operating temperature
Operating humidity (R.H., non condensing)
Degree of protection
Certifications & standards
FDA 510(k) clearance
Supplied accessories
Warranty
 
  • Eizo Library
    Eizo Library
  • Case Studies
    Case Studies
  • Videos
    Videos
  • Award&Reviews
    Award&Reviews